191186, St. Petersburg, Nevsky Ave., 30, Business center "Nevsky", office 3.19

8 (800) 333 30 35

sale@tes.spb.ru

KP request

For booking projects, please specify:

Transair-07

Physiotherapy apparatus for electrical stimulation Transair-07 is used for the treatment of sensorineural hearing loss by TES-therapy in combination with acoustic stimulation.

  • The device is intended for the treatment of sensorineural hearing loss using TES-therapy in combination with acoustic stimulation.
  • Tinnitus stops or becomes less intense in 91% of patients
  • Hearing improvement achieved in 89% of patients with sudden and acute hearing loss, and in 67% with chronic hearing loss
  • The ability to enter patient audiogram data into the device’s memory or determine hearing thresholds at standard frequencies in real time
Category: ,

Transair-07 (surdological)

Physiotherapy apparatus for electrical stimulation Transair-07 is used for the treatment of sensorineural hearing loss by TES-therapy in combination with acoustic stimulation.

The device is intended for the treatment of sensorineural hearing loss using TES-therapy in combination with acoustic stimulation.

Tinnitus stops or becomes less intense in 91% of patients

Hearing improvement achieved in 89% of patients with sudden and acute hearing loss, and in 67% with chronic hearing loss

The ability to enter patient audiogram data into the device’s memory or determine hearing thresholds at standard frequencies in real time

А+

The level of evidence-based medicine of class A

Safety

Safety and no side effects

30 +

More than 30 years of successful medical practice

Economy

Reducing drug costs and treatment time

Applications Transair-07

a method of treating a wide range of diseases by restoring the body’s natural defense mechanisms,
based on the activation of the production of endorphins.
Play Video

For healthy people

Maintaining a normal psycho-physiological state, the possibility of gaining psychological stability under any circumstances

Pain syndromes

Removal of pain of various origins and acceleration of healing. The result of anesthesia can be noticeable after the first procedure.

Treatment of depression

Effective application of the method in the treatment of various depressive conditions due to the production of stress-limiting hormones endorphins and serotonin

Transair-07

This Russian-made device allows you to carry out not only conventional TES-therapy procedures, but also implements additional features.

With the help of the device it is possible:

1. enter the patient’s audiogram data into the device’s memory or determine the hearing thresholds at standard frequencies directly on the device itself in real time;

2. Together with TES or separately from TES, perform the procedure of acoustic stimulation of the patient’s hearing organ (i.e., give an acoustic load – AN) with pure tones, with different sound duration and intensity of each tone, corresponding to the relief of the audiogram. The available results of clinical studies, confirmed by the analysis of the positive dynamics of short-latency auditory evoked potentials in patients with SHL, show high efficiency of the combined effect of TES and AN in almost 75% of patients. At the same time, the manifestation of the effect in patients who previously received TES-therapy without AN without effect should be noted.

Technical parameters:

  • Form of stimulating current:

• rectangular bipolar pulses;
  • Output signal adjustment range:

• rectangular bipolar pulses up to 3 mA;
  • Stimulating current frequency 77.5 Hz;

  • Number of audio stimulation channels 2;

  • Audio Stimulation Frequency (AC) 125; 250; 500; 1000; 2000; 4000; 8000 Hz;

  • Maximum sound pressure AC 120 dB;

  • The sounding time of octave frequencies is from 1 to 9 s;

  • Time of sessions TES + AS, TES, AS from 15 to 45 minutes;

  • Power supply: mains 220V, 50Hz;

  • Overall dimensions 290x200x155 mm;

  • Weight 3 kg;

  • The service life of the device is at least 5 years. The average time to failure is at least 3000 hours;

  • According to electrical safety, the device is classified according to GOST R 50267.0-92: portable, normal housing, long-term operation, class II type BF for the case of mains power.

Service functions

  • Auto-test of the device;

  • Display on the display: – current value of time and date; – the effective value of the stimulating current of the TES-effect; – time until the end of the treatment procedure; – sound pressure level and sounding time at different frequencies; – the selected operating mode.

  • Automatic smooth shutdown of the stimulating current of TPP and AC exposure and at the end of the procedure.

  • Multilevel patient protection system.

There are contraindications, you need to consult a specialist.

Useful videos on our channel!

Awards and achievements

About 80% of Russian medical institutions (more than 18,400) are equipped with magnetic therapy and diagnostic equipment of the company

1996 year

Medal to them. Academician P. L. Kapitsa for scientific discovery, priority of 1996.

2004 year

Award of the Government of the Russian Federation in the field of science and technology for 2004

2008 year

Grand Prix of the International exhibition-Congress "High Technologies. Innovation. Investments" Saint Petersburg.

2009 year

Grand Prix of the II International Congress of Inventors (Nomination "Invention that gives a push forward") Thailand.

2012 year

Award of the Government of the Russian Federation in the field of science and technology for 2012

History of the "TPP Center"

In 1991 in I.P.Pavlov Institute of Physiology of the Russian Academy of Sciences on the basis of the Sector of Transcranial Electrical Stimulation Mechanisms, headed by Doctor of Medical Sciences, Professor V.P. Lebedev, the scientific and practical center “Protective Mechanisms of the Brain” was created for the industrial production of TES-therapy devices. For six years, under the license of the authors of the method, the devices were produced under the brand name “ETRANS” at the Yaroslavl radio Plant. In 1996, the scientific and practical center was transformed into the TPP Center LLC, which began assembling the devices «TRANSAIR» (Transcranial electrical stimulator for Analgesia, Immunity and Repair) on its own production base.

Lebedev V. P.

Doctor of Medical Sciences, Professor, Honored Scientist of the Russian Federation, Academician of the Russian Academy of Natural Sciences, laureate of the USSR State Prize, twice laureate of the RF Government Prize in the field of science and technology; author of more than 400 scientific papers and 15 inventions.

Malygin A.V.

Candidate of Technical Sciences, twice laureate of the Russian Government Prize in science and technology; author of 80 scientific papers and more than 20 inventions, the main developer of equipment for thermal power plant therapy.

Interesting articles

20 discount%

Dear friends, there are two important dates ahead! The birthday of the Center TPP company and the Day of Russia, in honor of these two

More

May discount

from 30.04.22 to 15.05.22 there is a special price for the Doctor TES device Work schedule for May holidays: 30.04 – 03.05 weekend 04.05 –

More
Shopping cart

Запрос КП

Для бронирования проектов, укажите пожалуйста:

Нажимая на кнопку “Отправить”/”Подтвердить заказ”, я даю согласие на обработку персональных данных

KP request

For booking projects, please specify:

Leave a request